Search
文章正文
V-100 wear resistant steel plate hardness test
Published:2014-12-25 15:24:18    Text Size:【BIG】【MEDIUM】【SMALL
Summary:Samples should be well polished before test, and we should better get a average value after serval tests, this is because wear resistant steel plate metallographic distribution is not uniform.

Supplier: Zhangjiagang YaoYu Wear Resistant New Materials Co.,Ltd

Show you V-100 wear resistant steel plate Rockwell hardness test procedure and result

Test environment: Outdoor temperature 4-10 degree Celsius, dry.
                               Indoor temperature 15 degree Celsius, dry.

Two piece of 25*76mm, underwent Rockwell hardness test

We have desktop hardness tester in our factory, called Rockwell tester

 

The range of hardness of the sample ranged from HRC 58-60. (640/720 Vickers)

Notes before test:

Samples should be well polished before test, and we should better get a average value after serval tests, this is because wear resistant steel plate metallographic distribution is not uniform.

This is our metallographic:

Want to learn more about YaoYu ? Please feel free to contact Maggie Ma (maggiema03@163.com) for details

 


 

Download the attachment:www.wearresistantplatesteel.com (Has been downloaded 0 times)